| Paper | Title | Other Keywords | Page | ||
|---|---|---|---|---|---|
| TUPSA003 | Study of Efficiency of Beam Collimation at U-70 Accelerator by Use of Crystal Targets | proton, kicker, target, extraction | 38 | ||
|
New crystal technique bent crystal array and veer type reflector based on straight crystals were used like first stage in collimation system at U-70 accelerator. Efficiency of collimation was enhanced up to 90% in two-stage collimation system which included first crystal stage and long steel absorber like second stage. While in previous one-stage system without crystal only 40% protons hit deeply in absorber. For data taking and analysis of information modified modern beam diagnostic system was applied.
|
|
|