<?xml version="1.0" encoding="UTF-8"?>
<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Grewe, R.</author>
             <author>Arnold, M.</author>
             <author>Brauch, A.</author>
             <author>Dutine, M.</author>
             <author>Jürgensen, L.E.</author>
             <author>Pietralla, N.</author>
             <author>Schließmann, F.</author>
             <author>Schneider, D.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             In-Situ Quality Factor Measurements of SRF Cavities at S-DALINAC
          </title>
       </titles>
       <publisher>JACoW Publishing</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>2673-5504</isbn>
		 <isbn>978-3-95450-234-9</isbn>
		 <electronic-resource-num>10.18429/JACoW-SRF2023-MOPMB008</electronic-resource-num>
		 <language>English</language>
		 <pages>70-74</pages>
       <keywords>
          <keyword>cavity</keyword>
          <keyword>linac</keyword>
          <keyword>SRF</keyword>
          <keyword>coupling</keyword>
          <keyword>resonance</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2023</year>
          <pub-dates>
             <date>2023-09</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>https://doi.org/10.18429/JACoW-SRF2023-MOPMB008</url>
              <url>https://jacow.org/srf2023/papers/mopmb008.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          The Superconducting Darmstadt Linear Accelerator (S-DALINAC) is a thrice recirculating electron accelerator wich can be operated in a multi-turn energy recovery mode*. The design parameters for kinetic energy and beam current are up to 130 MeV and up to 20 uA respectively. The injector consists of a six-cell capture cavity and two 20-cell srf cavities. The main linac consists of eight 20-cell cavities. The cavities are operated at a temperature of 2 K with a frequency of 2.9972(1) GHz. Monitoring of the srf cavities is important for the overall performance of the accelerator. A key parameter for the rating of the srf cavity performance is the intrinsic quality factor Q. At the S-DALINAC it is measured for selected cavities during the yearly maintenance procedures. The unique design of the rf input coupler allows for a wide tuning range for the input coupling strength. This makes in-situ quality factor measurements using the decay time measurement method** possible. The contribution illustrates the principal design of the input couplers and the benefits it yields for Q measurements. Recent results including the progression of the quality factors over time will be presented.
       </abstract>
    </record>
  </records>
</xml>