A   B   C   D   E   F   G   H   I   K   L   M   O   P   Q   R   S   T   U   V   W  

tandem-accelerator

Paper Title Other Keywords Page
THPSC026 Status of HITS Injector ion, target, ion-source, vacuum 376
 
  • A. V. Semenov, V. G. Cherepkov, V. Klyuev, E. S. Konstantinov, E. A. Kuper, V. R. Mamkin, A. S. Medvedko, P. I. Nemytov, V. V. Repkov, V. B. Reva, R. A. Salimov, D. V. Senkov, V. A. Vostrikov
    BINP SB RAS, Novosibirsk
  Ion injector for cancer therapy facility HITS was designed and assembled at BINP. Injector is based on electrostatic tandem accelerator with 1.25 MV at the high voltage terminal. The negative ion beams are injected into tandem and charge exchanged in the vapor-magnesium target with vacuum heat insulation. The results of injector tests and working with carbon ion beam are presented.