A   B   C   D   E   F   G   H   I   K   L   M   O   P   Q   R   S   T   U   V   W  

diagnostics

Paper Title Other Keywords Page
TUPSA030 Beam Measurements With Visible Synchrotron Light on VEPP-2000 Collider controls, collider, vacuum, electron 104
 
  • Yu. A. Rogovsky, D. E. Berkaev, A. N. Kyrpotin, I. Nesterenko, A. L. Romanov
    BINP SB RAS, Novosibirsk
  This paper describes beam diagnostics at VEPP-2000 collider, based on visible synchrotron light analysis. These beam instruments include: SR beamline and optics; acquisition tools and high resolution CCD cameras distributed around the storage ring to measure the transverse beam profile and its position in vacuum chamber; photomultiplier tubes (PMT) which enables beam current measurements; video system. Some applications of these measurement systems and their measurement results are presented.  
 
TUPSA031 Profiles and Intensities Measurments in the Diagnostic System of the Extracted Beams of the U-70 Accselerator controls, optics, proton 107
 
  • A. Y. Sotnikov, N. Ivanova, A. V. Koshelev, V. Kovaltsov, A. Lukyantsev, S. Makonin, A. Matyushin, V. Milyutkin, V. S. Seleznev
    IHEP Protvino, Protvino, Moscow Region
  Diagnostic system for the extracted beams of the U-70 accelerator is a hardware-software complex with profilometers and electronic crates at the lower level, VME-crates with ADC-modules and MVME-167 processors (vxWorks operating system, basic EPICS tools, home made software) at the middle level, personal computers used as workstation at the upper level. In this report we consider: - the approaches to the system adaptation problems during the U-70 runs and solutions to these problems; - data acquisition and hardware-sofware levels of data processing for non-standard profilometers; - the tools for the beam intensity measurement and presentation, the intensimeter calibration procedure.  
 
WEPSB033 User Interface in the Diagnostic System of the Extracted Beams of the U-70 Accselerator controls, optics, site 242
 
  • A. Y. Sotnikov, N. Ivanova, A. V. Koshelev, V. Kovaltsov, A. Lukyantsev, V. Milyutkin, Y. N. Smirnov
    IHEP Protvino, Protvino, Moscow Region
  User interface in the diagnostic system of extracted beams is described. It was developed under Linux operating system on the personal computers used as workstations. The considered program tools provide: - the representation on operator consoles (workstations) information about beam profiles, intensity, displacement, root-mean-square error etc. in different forms; - the dynamic adjustment of the diagnostic system; - web presentation of the currrent information about the extracted beams; - data transfer to physical setups; - special beam characteristics calculation by the profilometer individual units data (for research purposes); - data archiving and web facilities for data viewing.