<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Capobianco-Hogan, K.G.</author>
             <author>Adhyatman, A.A.</author>
             <author>Arrowsmith-Kron, G.</author>
             <author>Bello Portmann, G.</author>
             <author>Bhatti, D.B.</author>
             <author>Cervantes, R.</author>
             <author>Coe, B.D.</author>
             <author>Deshpande, A.</author>
             <author>Feege, N.</author>
             <author>Jeffas, S.P.</author>
             <author>Krahulik, T.C.</author>
             <author>LaBounty, J.J.</author>
             <author>LaByer, T.M.</author>
             <author>Oliveira, A.</author>
             <author>Powers, H.A.</author>
             <author>Sekelsky, R.S.</author>
             <author>Shethna, V.D.</author>
             <author>Ward, N.</author>
             <author>van Nieuwenhuizen, H.J.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             Magnetic Cloaking of Charged Particle Beams
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-180-9</isbn>
		 <electronic-resource-num>10.18429/JACoW-NAPAC2016-TUPOB43</electronic-resource-num>
		 <language>English</language>
		 <pages>588-591</pages>
       <pages>TUPOB43</pages>
       <keywords>
          <keyword>ion</keyword>
          <keyword>electron</keyword>
          <keyword>detector</keyword>
          <keyword>superconducting-magnet</keyword>
          <keyword>dipole</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2017</year>
          <pub-dates>
             <date>2017-01</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>http://dx.doi.org/10.18429/JACoW-NAPAC2016-TUPOB43</url>
              <url>https://jacow.org/napac2016/papers/tupob43.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          In order to measure the momentum of particles produced by asymmetric collisions in the proposed Electron Ion Collider, a magnetic field should be introduced perpendicular to the path of the beam to increase momentum resolution without bending or depolarizing it. A magnetic cloak consisting of a superconducting magnetic shield surrounded by a ferromagnetic layer is capable of shielding the interior from a magnetic field – thereby protecting the beam – without distorting the field outside of the cloak – permitting detector coverage at high pseudorapidity.
       </abstract>
    </record>
  </records>
</xml>