<?xml version="1.0" encoding="UTF-8"?>
<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Anton, J.W.J.</author>
             <author>Chu, M.</author>
             <author>Jiang, Z.</author>
             <author>Narayanan, S.</author>
             <author>Shu, D.</author>
             <author>Strzalka, J.</author>
             <author>Wang, J.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             Progress of Nano-Positioning Design for the Coherent Surface Scattering Imaging Instrument for the Advanced Photon Source Upgrade Project
          </title>
       </titles>
       <publisher>JACoW Publishing</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>2673-5520</isbn>
		 <isbn>978-3-95450-229-5</isbn>
		 <electronic-resource-num>10.18429/JACoW-MEDSI2020-TUPC09</electronic-resource-num>
		 <language>English</language>
		 <pages>196-198</pages>
       <keywords>
          <keyword>photon</keyword>
          <keyword>alignment</keyword>
          <keyword>detector</keyword>
          <keyword>laser</keyword>
          <keyword>scattering</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2021</year>
          <pub-dates>
             <date>2021-10</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>https://doi.org/10.18429/JACoW-MEDSI2020-TUPC09</url>
              <url>https://jacow.org/medsi2020/papers/tupc09.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          As part of the Advanced Photon Source Upgrade (APS-U) project, the Coherent Surface Scattering Imaging (CSSI) [1] instrument is currently being developed. One of the most important components of the CSSI instrument at the 9-ID beamline of the APS-U, the Kirkpatrick-Baez (K-B) mirror system, will focus hard X-rays to a diffrac-tion-limited size of 500 nanometers at a working distance of 550 mm. High angular stability (19 nrad for the hori-zontal mirror and 14 nrad for the vertical mirror) is speci-fied no just for the focused beamsize but, more important-ly, to ensure the beam stability at the detector position that is up to 24 m from the K-B mirrors. A large sample-to-detector distance (up to 23 m), one of the beamline’s unique features for achieving a sufficient coherent-imaging spatial oversampling, requires sample angular stability of 50 nrad. In CSSI scattering geometry, the vertically placed sample reflects X-rays in the horizontal direction at an extremely shallow angle. The design in-cludes two high-precision rotary stages for sample pitch (vertical axis) and yaw (horizontal axis). The current design of instrument’s nano-positioning stages [2] and metrology required to satisfy the stability and positioning requirements are discussed in this paper.
       </abstract>
    </record>
  </records>
</xml>