Precision mechanics
Automation
Paper Title Page
WEPH03 Design of New Beam Instrumentation for the ISOLDE Isotope Separator at CERN 205
 
  • W. Andreazza, M. Duraffourg, G.J. Focker, A. Miarnau Marin, D. Smakulska, J. Tassan-Viol, R. Veness
    CERN, Geneva, Switzerland
 
  The ISOLDE radioactive ion beam separator facility at CERN produces beams of short-lived isotopes for experiments in physics, material and medical science. New requirements for more precise measurement of profile, position and intensity has pushed the CERN beam instrumentation group to start the study of a new generation of ISOLDE beam instrumentation dedicated to the specific needs of this facility. This paper will describe the design and the development of a number of new ISOLDE instruments with the aim of achieving better performance, increased reliability and to facilitate maintenance in the radioactive environment. It will explain how modern technologies (i.e. magnetically coupled push pull, 3D additive machining) have been used to make a modern, precise and reliable beam instrumentation design.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEPH03  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)  
 
WEPH17 Adjusting Mechanism of Inter-Undulator Section for PAL XFEL 241
 
  • H.-G. Lee, J.H. Han, S.-H. Jeong, Y.G. Jung, H.-S. Kang, D.E. Kim, H.-S. Lee, S.B. Lee, B.G. Oh, K.-H. Park, H.S. Suh
    PAL, Pohang, Kyungbuk, Republic of Korea
 
  Pohang Accelerator Laboratory (PAL) has developed a SASE X-ray Free Electron Laser based on 10 GeV linear accelerator. The inter-Undulator (IU) support section was developed to be used in the intersections of the Undulator Systems. The IU supports consist of phase shifter, quadrupole magnet with mover, beam loss monitor, cavity BPM with mover, two corrector magnets and vacuum components. The adjusting mechanism of IU Support has manual alignment system to be easily adjusting the component. The mover of quadruple magnet and cavity BPM with submicron repeatability has auto-adjusting systems with stepping motor. The mover main specifications include compact dimensions and a ±1.5 mm stroke in the vertical and horizontal direction. Linear motion guide based on 5-phase stepping motors have been chosen. This paper describes the design of the stages used for precise movement and results of mechanical measurements including reproducibility will be reported.  
DOI • reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEPH17  
Export • reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml)