| TUPH30 | ALBA Synchrotron Light Source Liquefaction Helium Plant | 102 |
|
||
| ALBA is a 3rd generation Synchrotron Light facility with: 8 operational Beam Lines (BLs), a 2nd BL of Phase II under construction and 3 first Phase III BLs in design phase. Some user experiments require Liquid Helium (LHe) as a coolant. The resulting LHe consumption at ALBA is about 650 l/week. Thus far the vaporized helium, which results from the refrigeration of experiments and equipment, has been released into the atmosphere without being reused. Due to the increasing price of LHe, ALBA agreed with ICN2 (Catalan Institute of Nanoscience and Nanotechnology) to invest in a Liquefaction Helium Plant. Internal staff has carried out the project, installation and pressure equipment legalization of the plant, which is located in a new 80 m2 construction. Under operation the plant allows recycling up to 24960 litres of LHe per year, which is an 80% of the helium consumed at ALBA, by making the gaseous helium undergo through 3 main stages: recovery, purification and liquefaction. The plant, unique in Catalonia, will entail cost savings about 77% and will reduce vulnerability to supply disruptions. ICN2 will benefit from a part of the production due to their initial investment. | ||
|
Poster TUPH30 [1.946 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH30 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
WEOPMA02 |
Non-Contact Luminescence Lifetime Cryothermometry for Application in Vacuum Environment | |
|
||
|
Funding: The development of the non-contact luminescence lifetime cryothermometry system for the I23 beamline was supported by the Science and Technology Facilities Council through grant ST/K002929 Measurement of the temperature of cryogenically cooled samples in a vacuum environment is a challenging task that requires specialist technical solutions. A new technique enabling non-contact monitoring of temperature has been developed for the I23 beamline. The temperature is determined by measuring the luminescence decay constant of a Bi4Ge3O12 scintillation sensor. One of the main advantages of the non-contact thermometry system is elimination of any connections between the sensor and the readout system that makes it fully compatible with the vacuum environment and necessity of swift replacement and manipulation of the samples. The technique was applied to quantify the thermal performance of different sample mounts that has been used for MX experiment at I23 beamline. It has been shown that the magnitude of the temperature rise across the sample mounts varies in wide range from 60 to 110 K while the temperature of goniometer was 40 K. The obtained results not only explain previous empirical finding but also demonstrated how this technique can aid studies of the complex relationships between various parameters influencing the heat conductance and temperature of the samples. |
||
|
Slides WEOPMA02 [2.866 MB] | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| WEOPMA07 | Development of a New Sub-4k ARPES Endstation at PSI | 193 |
|
||
|
Funding: Swiss National Science Foundation (SNSF) project number 206021164016 In spring 2016 a project was started to renew the high-resolution ARPES endstation of the Surface/Interface Spectroscopy (SIS) beamline at PSI. The focus lay on achieving sample temperatures below 4 K while maintaining 6 degrees of freedom. This made it necessary to redesign all thermally active parts, such as the connection to the cryostat, the flexible braid that enables the tilt and azimuthal movement, the sample clamping as well as the thermal isolators that hold the clamping device in place. A newly introduced shield in the main analyser chamber, cooled by separate cryopumps, is used to remove nearly all radiation heat load. A major milestone has recently been taken, by running cryogenic tests on a test stand. The simplified setup reached sample temperatures of 3.35 K. The temperature loss from the cryostat to the sample was as low as 0.6 K. Encouraged by these results, it is believed that the final endstation will be able to reach temperatures even below 3 K. With the new cryo concept, the thermal performance seems to be mainly limited by the radiative heat load emitted by the analyser lens. The new endstation is planned to be in operation by spring 2019. |
||
|
Slides WEOPMA07 [3.122 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-WEOPMA07 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |