| Paper | Title | Page |
|---|---|---|
| TUOPMA07 | RF Fingers for the New ESRF-EBS Storage Ring | 11 |
|
||
| In the new ESRF-EBS (Extremely Brilliant Source) storage ring vacuum chambers assembly, with a reduced aperture and the new omega shape, RF fingers are a key component to ensure good vacuum conditions and reach the best possible machine performance. As a result, dedicated efforts were put into producing a more compact more robust more reliable and easier to assemble RF finger design for the new machine. The work was done in parallel on the beam coupling impedance reduction, which have a direct impact on the electron beam lifetime, and on the mechanical aspect with FEA validation and geometry optimization. Many test have been made, in a mechanical laboratory, including high resolution 3D computed tomography images in order to measure the electrical contact, and also in the existing ESRF storage ring with the electron beam, to validate the final design before launching the series production | ||
|
Slides TUOPMA07 [7.516 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUOPMA07 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUOPMA08 | Deformable RF Fingers with Axial Extension | 15 |
|
||
| RF fingers in a bellows assembly provide electrical continuity for the image current between adjacent vacuum chambers. They are required to absorb all misalignments between the two chambers while minimizing abrupt changes in the beam aperture. In addition, during bake-outs of the chambers the fingers are required to accommodate their large thermal expansions. The latter is achieved either by having a sliding-contact finger design or a deformable finger design. In this paper we describe a version of the deformable finger design which permits large compression, significant misalignments and axial extension. A novel method of fingers' fabrication, FE analysis and test results are presented. | ||
|
Slides TUOPMA08 [9.954 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUOPMA08 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH01 | Installation and Alignment of SESAME Storage Ring | 20 |
|
||
| SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) is the first international 3rd generation synchrotron light source in the Middle East region. This paper presents the method used for installing the Storage ring girders, magnets, vacuum chambers, straight sections, and how the alignment was done. The Installation have been done in a short time with few staff. It was hard and difficult, but went great. A substantial progress has been made in the design, construction and installation of the SESAME Mechanical Systems. All Storage Ring accelerator systems are ready and commissioned. | ||
|
Poster TUPH01 [2.697 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH01 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH02 | Collimator for ESRF-EBS | 23 |
|
||
| The function of the collimator is to localize the majority of the electron losses in the ESRF-EBS storage ring (SR). In addition, the collimator of the ESRF-EBS should absorb about 1200w of synchrotron radiation. For ESRF-EBS, the electron losses due to intra bunch scattering (Touschek scattering) will be higher than in the current ESRF SR. To control the level of radiation outside the storage ring tunnel and the activation level of the vacuum chambers, it is more efficient to localize the electron losses and block the radiations at one place rather than reinforce all of the SR tunnel shielding. The poster will show how the design has taken into account all the diverse requirements from a safety, accelerator physics, thermo-mechanical and mechanical point of view. | ||
|
Poster TUPH02 [1.569 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH02 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
TUPH07 |
The Thermo-Mechanical Stability at TPS | |
|
||
| The thermo-mechanical stability is crucial to the performance of an advanced light source. The effects of the temperature fluctuations, such as outdoor temperature, air temperature in the tunnel, surface temperature of the major components and the ground temperature in the accelerator building, to the position of the mechanical structure of the 3 GeV Taiwan Photon Source (TPS) were depicted. The correlations and routes of the thermo-mechanical effects were studied. | ||
|
Poster TUPH07 [0.633 MB] | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH08 | Aluminium and Bimetallic Vacuum Chambers for the New ESRF Storage Ring (EBS) | 36 |
|
||
| The ESRF is proceeding with the design and procurement of its new low emittance storage ring EBS (Extremely Brilliant Source project). This completely new storage ring requires a new vacuum system including UHV chambers with complex shape and strict geometrical and dimensional tolerances. In order to meet these requirements we decided to build about half of the chambers in aluminum alloy machined from the bulk, the only technology permitting to respect the requirements. The result are 128 chambers, 2.5m long, built in alloy 2219 with Conflat flanges custom made from the chamber supplier by explosion bonding. The production phase is nearly finished, the produced chambers satisfy completely the expectations. A second generation of experimental aluminum chambers was designed as a substitution of some steel ones in order to solve same geometrical difficulties. These chambers are very complex as they have steel-aluminum junctions in the body in order to accommodate bellows and beam position monitor buttons. The delivery of the first prototype of this type of chamber is previewed for June 2018. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH08 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH13 | Mechanical Design Challenges Building a Prototype 8-Pole Corrector Magnet | 50 |
|
||
| An innovative design was developed for an 8-pole corrector magnet for the APS upgrade program. This is a combined function magnet consisting of horizontal and vertical correctors as well as a skew quadrupole. This paper describes technical challenges presented by both the magnetic design and the interface constraints for the magnet. A prototype magnet was built, and extensive testing on the magnet confirmed that all magnetic and mechanical requirements were achieved. Improvements were identified during the manufacturing and testing of the prototype magnet. The final design of the magnet which has incorporated these improvements is discussed in the paper. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH13 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH16 | Hammerhead Support Design and Application at SSRF | 60 |
|
||
| Electron beam stability is very important for Shanghai Synchrotron Radiation Facility(SSRF). One of the major players on beam stability is the vibration stability of magnet support systems. This paper describes several kinds of hammerhead magnet support prototypes with different structures, materials and ground fixation. Modal and response analyses of these prototypes are contrasted by finite-element analysis(FEA) and tests. The design can be applied to guide and improve the mechanical structures and the stability of magnet support systems at SSRF and other light source facilities. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH16 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH17 | Design Considerations Associated with the Replacement of a Sextupole Magnet by a Short Wiggler in a Cell of the Diamond Storage Ring Lattice | 63 |
|
||
|
Now that all of the original straight sections in the Diamond storage ring are occupied, novel ways of converting bending magnet beamline locations into insertion device beamlines have been considered. Recently one cell of the 24 cells was reconfigured in to a Double-Double Bend Achromat (DDBA) to provide a new location for an Undulator and enable a formerly designated bending magnet beamline to become an Insertion Device Beamline*. Extending this concept for the new Dual Imaging and Diffraction (DIAD) Beamline proved to have a strong impact on lifetime and injection efficiency, so instead it was decided to remove a Sextupole magnet in one cell and substitute it with a short fixed gap Wiggler. The accelerator physics, mechanical and electrical design aspects associated with the change are described.
* Mechanical Engineering solutions for the Diamond DDBA Project, J Kay, MEDSI 2014 |
||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH17 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH18 | Vacuum Performance Test of CuCrZr Photon Absorbers | 66 |
|
||
| To test the pumping performance of NEG coated Cu-CrZr absorber, we performed a comparative experiment on the two absorbers, one with NGE coating and the other one without coating. First, we run the Monte Carlo simu-lation by using MolFlow+ code to estimate the pressure inside test chamber at different thermal outgassing rate. And then two absorbers are mounted inside the chamber for the pressure vs. time profiles testing. The experimental set-up and pressure profiles will be presented here. | ||
|
Poster TUPH18 [0.852 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH18 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH21 | Design of Vertical and Horizontal Linear Flexure Stages for Beam Size Monitor System | 72 |
|
||
| Taiwan photon source is a third generation accelerator with low emittance and high brightness. The electric beam size is one of important parameters to indicate the stabil-ity and to measure the emittance and coupling of light source. The aperture size of beam slitter is a crucial part to calculate the value of beam size in the X-ray pine-hole system. In order to obtain the more precise result of beam size, the flexure mechanism on beam slitter is applied for the adjustment of the aperture. This paper shows that the design concept and the measurement of the beam size are obtained by the new adjustment system. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH21 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH23 | Field Quality From Tolerance Analyses in Two-Half Sextuple Magnet | 78 |
|
||
|
Funding: Work supported by the U.S. Department of Energy, Office of Science, under Contract No. DE-AC02-06CH11357 Sextupole magnets are used extensively in particle ac-celerators, synchrotrons, and storage rings. Good magnet-ic field quality is needed in these magnets, which requires machining the magnet parts to high precision and is the primary driver of the high fabrication costs. To minimize the fabrication costs, a magnetic field quality study from tolerance analyses was conducted. In this paper, finite element analysis (FEA) using OPERA was performed to identify key geometric factors that affect the magnetic field quality and identify the allowable range for these factors. Next, geometric and dimensional tolerance stack-up analyses are carried out using Teamcenter Variation Analysis to optimize the allocation of the geometric tol-erances to parts and assemblies. Finally, the analysis re-sults are compared to magnetic measurements of a R&D sextupole magnet. |
||
|
Poster TUPH23 [1.027 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH23 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH24 | Front End of Dual Imaging and Diffraction Beamline at Diamond Light Source | 81 |
|
||
| The Dual Imaging and Diffraction (DIAD) beamline X-ray source is a ten pole mini wiggler. By locating the mini wiggler in place of an existing sextupole magnet, the DIAD beamline is built at a bending magnet beamline position in Diamond. To accommodate the unusual beam trajectory, a new front end was designed for the DIAD beamline. The particular designs and specifications including an improved front end slits design, as well as the synchrotron and dipole ray tracing of the front end are presented in this paper. The development process of delivering the front end - the project challenges, approach and activities are also described along with the technical challenges. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH24 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH27 | Structure Design of a Multi-Wire Target | 92 |
|
||
| Introduce a structure design of a Multi-Wire Target. The plan of wire alignment was decided by analysis. The wire tightening device with interlaced alignment was used to solve the wire alignment in narrow space. The vacuum chamber was designed by optimization. The displacement pickup was used to make the movement control of translation stages. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH27 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH28 | Calculation of Orbit Distortions for the APS Upgrade Due to Girder Resonances | 95 |
|
||
| Maintaining sub-micron-scale beam stability for the APS-U Multibend Achromat Lattice places strict requirements on the magnet support system. Historically, magnet vibration requirements have been based on physics simulations which make broad generalizations and assumptions regarding the magnet motion. Magnet support systems have been notoriously difficult to analyze with FEA techniques and as a consequence, these analyses have been underutilized in predicting accelerator performance. The APS has developed a procedure for accurate modeling of magnet support systems. The girder mode shapes are extracted from these analyses and exported to accelerator simulation code elegant to calculate the static beam amplification factor for each mode shape. These amplification factors, along with knowledge of damping coefficients and the character of the tunnel floor motion, may then be used to predict the effect of girder resonances on beam stability and validate the magnet support designs. | ||
|
Poster TUPH28 [0.848 MB] | |
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH28 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH33 | Vibration Measurement & Simulation of Magnet & Girder in SESAME | 111 |
|
||
|
Funding: IAEA SESAME (Synchrotron-light for Experimental Science and Applications in the Middle East) started operation in January 2017. During the design phase several FEA studies were performed to optimize the girder and the magnet design taking into account all the constraints such as the tight spacing between magnets, the vacuum chamber installation interactions with the magnets. In this paper the experimental and Numerical modal analysis are presented as well as the result comparison between the experimental and simulation work. |
||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH33 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |
| TUPH41 | Investigation of Regulation Plan for the Vibration Utility Equipment of HEPS | 136 |
|
||
| For the third or fourth generation synchrotron light sources, the brilliance of the x-ray beam is 2 to 3 order higher than other generations, and in the meanwhile the beam emittance is at least one order smaller. To ensure the stability of the beam, the vibration caused beam motion is usually controlled to be within 10% of the RMS beam size. Thus the smaller beam emittance is, more restrict of the regulation plan to the vibration sources should be. Inside of the light source site, one major vibration source is the utility equipment such as water pump, compressors and so on. There are two controlling approaches for the vibration amplitude of those sources, one is damping, and another way is decay. However reasonable specification is the key of the controlling method. This work will present the detailed establish process of the regulation plan for HEPS in China. | ||
| DOI • | reference for this paper ※ https://doi.org/10.18429/JACoW-MEDSI2018-TUPH41 | |
| Export • | reference for this paper using ※ BibTeX, ※ LaTeX, ※ Text/Word, ※ RIS, ※ EndNote (xml) | |