<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Holmes, M. R.</author>
             <author>Amores, L.</author>
             <author>Castagna, J.C.</author>
             <author>James, J.H.</author>
             <author>Osipov, T.</author>
             <author>Walter, P.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             DREAM - A New Soft X-ray (Dynamic REAction Microscopy) COLTRIMS Endstation at LCLS-II
          </title>
       </titles>
		 <publisher>JACoW Publishing</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-207-3</isbn>
		 <electronic-resource-num>10.18429/JACoW-MEDSI2018-THPH21</electronic-resource-num>
		 <language>English</language>
		 <pages>382-384</pages>
       <pages>THPH21</pages>
       <keywords>
          <keyword>laser</keyword>
          <keyword>vacuum</keyword>
          <keyword>optics</keyword>
          <keyword>diagnostics</keyword>
          <keyword>coupling</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2018</year>
          <pub-dates>
             <date>2018-12</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>https://doi.org/10.18429/JACoW-MEDSI2018-THPH21</url>
              <url>http://jacow.org/medsi2018/papers/thph21.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          SLAC is building new soft X-ray beamlines to take advantage of the LCLS-II upgrade to 1 MHz. One of the new beamlines is called TMO (Time resolved Molecular Optical science) also known as NEH 1.1. It will be a soft X-ray beamline featuring a sub-micron X-ray focus at its second, most downstream interaction region where the DREAM COLTRIMS (COld Target Recoil Ion Momentum Spectroscopy) endstation will be situated. DREAM will feature; large magnetic coils to provide a strong uniform magnetic field through the spectrometer, rigid in-vacuum laser in- &amp; out-coupling optics decoupled from the chamber support stand for pump-probe experiments, a multi-stage differentially pumped gas jet with catcher, insertable diagnostics, a long-distance microscope, scatter slits, a steerable gas jet, jet slits, and an adjustable stand to bias the spectrometer off-center from the interaction region. In order to achieve a spot overlap spec of 0.5 um; the KB mirrors, laser optics, &amp; beam position diagnostics all sit on a common granite support structure to minimize mechanical vibrations and thermal drifts. An in-vacuum UHV hexapod will be utilized for fine positioning of the laser in-coupling optic.
       </abstract>
    </record>
  </records>
</xml>
