TY - CONF AU - Ericson, E.J. AU - Bertwistle, D. AU - Boland, M.J. AU - Castillo Sosa, M. AU - Pelz, D. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Simulation and Analysis of Wake Fields and Trapped RF Modes in Insertion Device Vacuum Chambers at the Canadian Light Source J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The Canadian Light Source (CLS) synchrotron operates with four in-vacuum insertion devices, three in-vacuum undulators, and one in-vacuum wiggler. Presently, each of the devices occupies half of a straight section. The wiggler is unique in our ring as it is both in-vacuum and shares a straight section with an in-vacuum undulator. We have observed gap dependent beam instabilities in the undulator located in the straight section. In order to better understand the problem, the cause of the instabilities was investigated using 3D electromagnetic modelling. First, the ’trapped’ RF modes (natural resonances) for this undulator chamber, their Q value, and their peak frequencies were analysed using Eigenmode simulation. Secondly, beam excitation of the Eigenmodes was simulated with the Wakefield solver. Herein we present the results of this electromagnetic modelling. PB - JACoW Publishing CP - Geneva, Switzerland SP - 414 EP - 416 KW - vacuum KW - simulation KW - undulator KW - insertion-device KW - insertion DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-MOPGW128 UR - http://jacow.org/ipac2019/papers/mopgw128.pdf ER - TY - CONF AU - Giansiracusa, P.J. AU - Boland, M.J. AU - Lafky, M.P. AU - Lucas, T.G. AU - Rassool, R.P. AU - Volpi, M. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - The Effect of the SLED Installation on Extracted and Lost Beam at the Australian Synchrotron Linac. J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - A recent upgrade to the high power RF network of the linac at the Australian Synchrotron included a SLED Type 1 Pulse Compressor allowing for the operation of its 100 MeV linac using a single klystron. We explore the effects of the SLED installation on the properties of the beam extracted from the linac with a particular focus on the energy spread and bunch train profile. Additionally, the optical fibre beam loss monitor (oBLM), also recently commissioned, was employed to provide shot-by-shot feedback on loss location and intensity to investigate the change in beam losses. PB - JACoW Publishing CP - Geneva, Switzerland SP - 2794 EP - 2797 KW - linac KW - synchrotron KW - network KW - klystron KW - injection DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-WEPRB001 UR - http://jacow.org/ipac2019/papers/weprb001.pdf ER - TY - CONF AU - Samadi, N. AU - Chapman, L.D. AU - Dallin, L.O. AU - Shi, X. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Application of a Phase Space Beam Position and Size Monitor for Synchrotron Radiation J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - We will report on a system (ps-BPM) that can measure the electron source vertical position and angular motion along with the vertical source size and angular size at a single location in a synchrotron bend magnet beamline*. This system uses a combination of a monochromator and a filter with a K-edge to which the monochromator was tuned in energy. The vertical distribution of the beam with and without the filter was simultaneously visualized with an imaging detector. The small range of angles from the source onto the monochromator crystals creates an energy range that allows part of the beam to be below the K-edge and the other part above. Measurement of the beam vertical location without the absorber and edge vertical location with the absorber allowes measurement of the source position and angle. The beam width and edge width give information about the vertical electron source size and angular distribution. The ps-BPM measurements have been made where the electron beam size and angular distribution was adjusted using skew quads. The ps-BPM measurements correlate well with modeling of the ps-BPM system as well as conventional beam size measurements using a pinhole. PB - JACoW Publishing CP - Geneva, Switzerland SP - 4376 EP - 4379 KW - electron KW - synchrotron KW - detector KW - synchrotron-radiation KW - radiation DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-FRXXPLS3 UR - http://jacow.org/ipac2019/papers/frxxpls3.pdf ER -