TY - CONF AU - Knafel, M.A. AU - Madura, M. AU - Wawrzyniak, A.I. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Development of RF Interlock and Diagnostics Systems in SOLARIS Storage Ring J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The purpose of this document is to describe and asses the operation of various devices that have been developed, constructed and tested by RF team in NSRC SOLARIS . One of those devices is used as additional safety interlock for the tuning mechanism of main 100MHz active cavities. The other is a stripline feeding network, that in cooperation with BPM receiving network will excite the beam providing the diagnostics group with a new option for tune measurement. Each device shall have its principle of operation explained and construction details revealed. Finally, all devices will be assesed over their operational lifetime in our facility. PB - JACoW Publishing CP - Geneva, Switzerland SP - 3082 EP - 3083 KW - network KW - cavity KW - storage-ring KW - synchrotron KW - betatron DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-WEPRB115 UR - http://jacow.org/ipac2019/papers/weprb115.pdf ER - TY - CONF AU - Jaglarz, M.B. AU - Wawrzyniak, A.I. AU - Wikłacz, J. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Radiation Safety at SOLARIS 1.5 GeV Storage Ring J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - Radiation measurements at Solaris are continuously performed by using 9 radiation monitor stations (RMS) located around the storage ring and the beamlines area. 4 of RMS are connected to the Personal Safety System and in case of exceeding alarm level dump the beam or close safety shutters. Moreover thermoluminescence dosimeters (TLDs) are used to registered doses in the classified areas according to the Polish regulation. Measurements are performed since 2015 when the commissioning of the storage ring has started. Since that time several improvements to the radiation shielding was done to fulfill the ALARA principle. Moreover the electron beam optimizations during the injection, ramping and operation were performed to decrease the electrons losses and the radiation level. This presentation will report on radiation measurements results obtained before and after the chopper installation. Additionally problems with radiation level while the beam current is increasing to the designed 500mA value will be presented. PB - JACoW Publishing CP - Geneva, Switzerland SP - 3940 EP - 3942 KW - radiation KW - storage-ring KW - injection KW - electron KW - MMI DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-THPRB059 UR - http://jacow.org/ipac2019/papers/thprb059.pdf ER -