TY - CONF AU - Fomichev, V.A. AU - Chinin, A.A. AU - Kozlov, S.G. AU - Kuropatkin, Yu.P. AU - Nizhegorodtsev, V.I. AU - Romanov, I.N. AU - Savchenko, K.V. AU - Selemir, V.D. AU - Shamro, O.A. AU - Urlin, E.V. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Mobile Accelerator Based on Ironless Pulsed Betatron for Dynamic Objects Radiographing J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The paper concerns a mobile accelerator based on the ironless pulsed betatron. The accelerator has a possibility to obtain up to three frames in a single pulse and is aimed to radiograph dynamic objects with a large optical thickness. The block diagram of the accelerator, the temporal diagram of its separate systems operation and oscillograms of the betatron output parameters are provided. The testing powering in a single frame mode was carried out in 2018. The capacitance of the storage of the betatron electromagnet pulsed powering system that defines the electron beam energy was equal to 1800 μF. The following test results have been obtained. The thickness of the lead test object examined with X-rays reached 140 mm at 4 m from the tantalum target of the betatron. The full width of the output gamma pulse at half maximum in a single frame mode was equal to 120 ns; the dimension of the radiation source was 6 mm x 3 mm; the dimension of the tantalum target was 6 mm x 6 mm. The application of these accelerators within the radiographic complex* enables the optimization of the hydrodynamic experiments geometry resulting in the increase of the test efficiency. PB - JACoW Publishing CP - Geneva, Switzerland SP - 3500 EP - 3502 KW - betatron KW - electron KW - radiation KW - ion-source KW - target DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-THPMP026 UR - http://jacow.org/ipac2019/papers/thpmp026.pdf ER - TY - CONF AU - Shamro, O.A. AU - Chinin, A.A. AU - Fomichev, V.A. AU - Kuropatkin, Yu.P. AU - Nizhegorodtsev, V.I. AU - Savchenko, K.V. AU - Selemir, V.D. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Concept of Radiographic Complex Based on Ironless Pulsed Betatrons for Small-Angle Tomography J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The active research complexes intended for the radiography of dynamic objects with a high optical density are reviewed. The concept of a multi-beam radiographic complex for a small-angle tomography based on ironless pulsed betatrons is proposed*. It is possible to use up to 18 compact facilities in a complex; they are located in three horizontal planes. The test object is placed in the explosion-proof chamber. Each facility consists of two typical units: an accelerator unit, and a unit of the electromagnet pulsed powering system. The output parameters of the facility are the maximum translucent capacity of 200 mm of the lead at 1 m from the betatron target, the resolution of less than 1 mm, the gamma-pulse full width at half maximum of 100 ns in a single frame mode, the gamma-pulse full width at half maximum of 150 ns in a three-frame mode. The complex will be able to obtain up to 54 frames in one hydrodynamic experiment at the operation of each facility in a three-frame mode. The complex is compact. Its diameter with a service area will be 20 m. PB - JACoW Publishing CP - Geneva, Switzerland SP - 3503 EP - 3505 KW - betatron KW - radiation KW - experiment KW - collimation KW - ion-source DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-THPMP027 UR - http://jacow.org/ipac2019/papers/thpmp027.pdf ER -