TY - CONF AU - Villari, A.C.C. AU - Crisp, D.B. AU - Lapierre, A. AU - Nash, S. AU - Summers, T. AU - Zhao, Q. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Energy Calibration of the Rea3 Accelerator by Time-of-Flight Technique* J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - We report on a simple method to perform an absolute calibration of the magnetic beam analyser of the reaccelerator ReA3 at the National Superconducting Cyclotron Laboratory. The method is based on the time of flight between two beam stoppers 7.65 m apart. Based on two independent time-of-flight measurements at three different beam energies, the beam analyser magnet is calibrated with an accuracy of 0.12 %, corresponding to a beam energy accuracy of 0.24 %. PB - JACoW Publishing CP - Geneva, Switzerland SP - 2760 EP - 2762 KW - dipole KW - cyclotron KW - linac KW - detector KW - electron DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-WEPGW112 UR - http://jacow.org/ipac2019/papers/wepgw112.pdf ER - TY - CONF AU - Wu, X. AU - Alt, D.M. AU - Blosser, G.F. AU - Horner, G.S. AU - Neville, Z.S. AU - Paquette, J.M. AU - Usher, N.R. AU - Vincent, J.J. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Recent Progress in R&D for Ionetix Ion-12SC Superconducting Cyclotron for Production of Medical Isotopes J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The Ion-12SC is a sub-compact, 12.5 MeV proton su-perconducting isochronous cyclotron for commercial medical isotope production recently developed at Ionetix Corporation [1]. The machine features a patented cold steel and cryogen-free conduction cooling magnet, a low power internal cold-cathode PIG ion source, and an inter-nal liquid target [2]. It was initially designed to produce N-13 ammonia for dose on-demand cardiology applica-tions but can also be used to produce F-18, Ga-68 and other medical isotopes widely used in Positron Emission Tomography (PET). The 1st engineering prototype was completed and commissioned in September 2015, and four additional units have been completed since [3]. The first two units have been installed and operated at the University of Michigan and MIT. R&D efforts in physics and engineering have continued to improve machine performance, stability and reliability. These improve-ments include: 1) Water cooling added to the dummy dee to limit the operating temperature of the ion source to improve lifetime and performance, 2) Magnetic field maps, obtained with a Hall probe based mapper, were used to accurately measure the isochronism and provide information needed to compensate for any unwanted 1st harmonics and 3) Feedback based control methods ap-plied to regulate the beam intensity on target by adjusting the ion source cathode current. The C1 unit installed at the University of Michigan Medical School early this year treated ~100 patients/month with N-13 ammonia. The machines are now capable of routinely producing > 21 doses/day with > 99% availability. The Ionetix manu-facturing facility is capable of producing up to 30 ma-chines per year. PB - JACoW Publishing CP - Geneva, Switzerland SP - 3568 EP - 3570 KW - cyclotron KW - ion-source KW - target KW - controls KW - cathode DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-THPMP052 UR - http://jacow.org/ipac2019/papers/thpmp052.pdf ER -