TY - CONF AU - Poirier, F. AU - Blain, G. AU - Bulteau-harel, F. AU - Fattahi, M. AU - Goiziou, X. AU - Haddad, F. AU - Koumeir, C. AU - Letaeron, A. AU - Vandenborre, J. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - The Pulsing Chopper-Based System of the Arronax C70XP Cyclotron J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The Arronax Public Interest Group (GIP) uses a multi-particle cyclotron to perform irradiation from a few pA up to hundreds of uA on various experiments and targets *. To support further low intensity usage and extend the beam time structure required for experiments such as pulsed experiments studies (radiolysis, proton therapeutic irradiation) and high intensity impact studies, it has been devised a pulsing system in the injection of the cyclotron. This system combines the use of a chopper, low frequency switch, and a control system based on the new extended EPICS network. This paper details the pulsing system adopted at Arronax, the last results in terms of time structure, various low intensity experimental studies performed with alpha and proton beams and the dedicated photon diagnostics. PB - JACoW Publishing CP - Geneva, Switzerland SP - 1948 EP - 1950 KW - cyclotron KW - controls KW - solenoid KW - proton KW - injection DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-TUPTS008 UR - http://jacow.org/ipac2019/papers/tupts008.pdf ER - TY - CONF AU - Sengar, A. AU - Goiziou, X. AU - Gomez Serito, F. AU - Haddad, F. AU - Koumeir, C. AU - Poirier, F. ED - Boland, Mark ED - Tanaka, Hitoshi ED - Button, David ED - Dowd, Rohan ED - Schaa, Volker RW ED - Tan, Eugene TI - Development of a Beam Loss Monitor and Transverse Beam Dynamics Studies at ARRONAX C70XP Cyclotron J2 - Proc. of IPAC2019, Melbourne, Australia, 19-24 May 2019 CY - Melbourne, Australia T2 - International Particle Accelerator Conference T3 - 10 LA - english AB - The ARRONAX Interest Public Group uses a multi-particle, high energy and high intensity industrial accelerator which has several beamlines used for various purposes. For improvement of operations, ARRONAX has foster and installed robust air-based Beam Loss Monitors (BLMs) outside the beam pipes. BLMs consist of four active detecting plates and are integrated within the experimental physics and industrial control system (EPICS) monitoring and data acquisition system. Each BLM has been tested for the pre-commissioning phase with beams at low intensity (600pA to 6nA on target). Comparative studies and selection of the BLMs has led to their installation at high intensity beam lines. BLMs are now used in beam dynamics studies to investigate transverse characteristics while in regular operation. They support present and future operations extension foreseen at ARRONAX. The results from experimental studies on BLMs at low beam intensity and status of beam dynamics studies at high intensity (A) are presented here. Keywords: BLM, beam dynamics, EPICS, Gas ionization detector, cyclotron, proton. PB - JACoW Publishing CP - Geneva, Switzerland SP - 2470 EP - 2472 KW - cyclotron KW - experiment KW - radiation KW - operation KW - quadrupole DA - 2019/06 PY - 2019 SN - 978-3-95450-208-0 DO - DOI: 10.18429/JACoW-IPAC2019-WEPGW006 UR - http://jacow.org/ipac2019/papers/wepgw006.pdf ER -