<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Simon, M.</author>
             <author>Bai, M.</author>
             <author>Bobnar, J.</author>
             <author>Böhme, C.</author>
             <author>Hinder, F.</author>
             <author>Lorentz, B.</author>
             <author>Malec, J.</author>
             <author>Marusic, A.</author>
             <author>Modic, R.</author>
             <author>Weidemann, C.</author>
             <author>Žagar, K.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             COSY Slow Orbit Feedback System
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-182-3</isbn>
		 <electronic-resource-num>10.18429/JACoW-IPAC2017-TUPIK050</electronic-resource-num>
		 <language>English</language>
		 <pages>1802-1805</pages>
       <pages>TUPIK050</pages>
       <keywords>
          <keyword>controls</keyword>
          <keyword>closed-orbit</keyword>
          <keyword>EPICS</keyword>
          <keyword>feedback</keyword>
          <keyword>dipole</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2017</year>
          <pub-dates>
             <date>2017-05</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>http://dx.doi.org/10.18429/JACoW-IPAC2017-TUPIK050</url>
              <url>http://jacow.org/ipac2017/papers/tupik050.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          The Cooler Synchrotron (COSY) at Forschungszentrum Jülich is currently carrying out the preparation for a direct measurement of the electric Dipole Moment (EDM) of the deuteron using an RF Wien filter*,**. In a magnetic storage ring with the spin vector aligned along the direction of motion, the EDM manifests in a buildup of the vertical spin component. Besides this signal, radial magnetic fields due to a distortion of the vertical closed orbit can produce a similar signal. This signal is a systematic limit of the proposed measurement procedure. Based on simulation studies***, a vertical closed orbit distortion with a RMS smaller than 0.1 mm is required to achieve a sensitivity of 10⁻¹⁹ e.cm or better. In order to accomplish this challenging goal, a slow orbit feedback system was proposed and recently commissioned at COSY. The design and commissioning results will be presented, and the future plan will also be discussed.
       </abstract>
    </record>
  </records>
</xml>