<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Mete Apsimon, O.</author>
             <author>Hanahoe, K.</author>
             <author>Pacey, T.H.</author>
             <author>Xia, G.X.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             A Gas-filled Capillary Based Plasma Source for Wakefield Experiments
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-147-2</isbn>
		 <electronic-resource-num>10.18429/JACoW-IPAC2016-WEPMY026</electronic-resource-num>
		 <language>English</language>
		 <pages>2613-2616</pages>
       <pages>WEPMY026</pages>
       <keywords>
          <keyword>plasma</keyword>
          <keyword>vacuum</keyword>
          <keyword>high-voltage</keyword>
          <keyword>experiment</keyword>
          <keyword>simulation</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2016</year>
          <pub-dates>
             <date>2016-06</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>http://dx.doi.org/10.18429/JACoW-IPAC2016-WEPMY026</url>
              <url>http://jacow.org/ipac2016/papers/wepmy026.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          A plasma medium can be formed when a gas is discharged via an applied high voltage within a capillary tube. A high voltage discharge based plasma source for plasma wake- field acceleration experiment is being developed. Design considered a glass capillary tube with various inner radii. Glass was preferred to sapphire or quartz options to ease the machining. Electrodes will be attached to the tube using a sealant resistant to high vacuum conditions and baking at high temperatures. Each electrode will be isolated from the neighbouring one using nuts or washers from a thermoplastic polymer insulator material to prevent unwanted sparking outside of the tube. In this paper, general design considerations and possible working points of this plasma source are presented for a range of plasma densities from 1×10²⁰ to 1×10²² m^{&}#8722;3. Consideration was also given to plasma density diagnostic techniques due to critical dependence of accelerating gradient on plasma density.
       </abstract>
    </record>
  </records>
</xml>
