<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Schmitzer, C.</author>
             <author>Farinon, F.</author>
             <author>Garonna, A.</author>
             <author>Kronberger, M.</author>
             <author>Kulenkampff, T.K.D.</author>
             <author>Kurfürst, C.</author>
             <author>Myalski, S.</author>
             <author>Nowak, S.</author>
             <author>Osmić, F.</author>
             <author>Penescu, L.C.</author>
             <author>Pivi, M.T.F.</author>
             <author>Urschütz, P.</author>
             <author>Wastl, A.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             MedAustron Synchrotron RF Commissioning for Medical Proton Beams
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-147-2</isbn>
		 <electronic-resource-num>10.18429/JACoW-IPAC2016-MOPOY001</electronic-resource-num>
		 <language>English</language>
		 <pages>844-846</pages>
       <pages>MOPOY001</pages>
       <keywords>
          <keyword>injection</keyword>
          <keyword>acceleration</keyword>
          <keyword>synchrotron</keyword>
          <keyword>proton</keyword>
          <keyword>cavity</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2016</year>
          <pub-dates>
             <date>2016-06</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>http://dx.doi.org/10.18429/JACoW-IPAC2016-MOPOY001</url>
              <url>http://jacow.org/ipac2016/papers/mopoy001.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          MedAustron is a medical accelerator facility for hadron therapy cancer treatment using protons and carbon ions. The Synchrotron is driven by a 0.47-3.26 MHz Finemet® loaded wideband cavity powered by 12x 1kW solid state amplifiers connected to a digital Low Level RF system. It was developed in collaboration with CERN and put to operation at MedAustron in early 2014. The main Synchrotron RF (sRF )commissioning steps for proton beams involved the setup of the adiabatic capture process, the setup of the frequency and voltage ramps and feedback loops for fast acceleration and the RF jump for extraction. The adiabatic capture process was optimized in terms of energy and voltage mismatch by analyzing longitudinal empty bucket scans after beam injection into the synchrotron. The acceleration ramp optimization was based on calculations using a software tool developed in-house and adapted experimentally to minimize losses at injection and during acceleration. This paper provides an overview of the acceleration system and describes the commissioning process of the sRF system and the related beam commissioning efforts at MedAustron.
       </abstract>