| Title |
Commissioning of SESAME Booster |
| Authors |
- M. Attal, I.A. Abid, T.H. Abu-Hanieh, H. Al-Mohammad, M.A. Al-Najdawi, D.S. Foudeh, A. Hamad, E. Huttel, A. Ismail, S.Kh. Jafar, F. Makahleh, M. Mansouri Sharifabad, K. Manukyan, I. Saleh, N.Kh. Sawai, M.M. Shehab
SESAME, Allan, Jordan
|
| Abstract |
Commissioning of the 800 MeV booster of SESAME light source started in December 2013. The 38.4 m circumference booster is a part of SESAME injector which includes also a 20 MeV classical microtron as a pre-injector that is in operation since 2012. The main results and experience obtained during the commissioning period are reported in this paper.
|
| Paper |
download WEPOW024.PDF [0.775 MB / 3 pages] |
| Export |
download ※ BibTeX
※ LaTeX
※ Text/Word
※ RIS
※ EndNote |
| Conference |
IPAC2016, Busan, Korea |
| Series |
International Particle Accelerator Conference (7th) |
| Proceedings |
Link to full IPAC2016 Proccedings |
| Session |
Poster Session |
| Date |
11-May-16 16:00–18:00 |
| Main Classification |
02 Photon Sources and Electron Accelerators |
| Sub Classification |
A05 Synchrotron Radiation Facilities |
| Keywords |
booster, injection, septum, quadrupole, extraction |
| Publisher |
JACoW, Geneva, Switzerland |
| Editors |
Christine Petit-Jean-Genaz (CERN, Geneva, Switzerland); Dong Eon Kim (PAL, Pohang, Republic of Korea); Kyung Sook Kim (PAL, Pohang, Republic of Korea); In Soo Ko (POSTECH, Pohang, Republic of Korea); Volker RW Schaa (GSI, Darmstadt, Germany) |
| ISBN |
978-3-95450-147-2 |
| Published |
June 2016 |