| Title |
Field Error Correction Considerations of Cryogenic Permanent Magnet Undulator (CPMU) for High Energy Photon Source Test Facility (HEPS-TF)* |
| Authors |
- Y.F. Yang, H.H. Lu, S.C. Sun, X.Z. Zhang
IHEP, Beijing, People's Republic of China
|
| Abstract |
Considerations are made for field error corrections of a 2m-long CPMU in built for HEPS-TF. Field changes in cooling to liquid nitrogen temperature are simulated. 1st field integral of terminal changes by tens of Gauss cm and RMS of phase errors induced by cold contraction is less than 1° when temperature gradient along girder is below 1.5K/m. Field signature of magic finger is unchanged with temperature. Strategy of the field error correction is discussed.
|
| Paper |
download THPOW041.PDF [1.047 MB / 3 pages] |
| Export |
download ※ BibTeX
※ LaTeX
※ Text/Word
※ RIS
※ EndNote |
| Conference |
IPAC2016, Busan, Korea |
| Series |
International Particle Accelerator Conference (7th) |
| Proceedings |
Link to full IPAC2016 Proccedings |
| Session |
Poster Session |
| Date |
12-May-16 16:00–18:00 |
| Main Classification |
02 Photon Sources and Electron Accelerators |
| Sub Classification |
T15 Undulators and Wigglers |
| Keywords |
cryogenics, undulator, simulation, operation, electron |
| Publisher |
JACoW, Geneva, Switzerland |
| Editors |
Christine Petit-Jean-Genaz (CERN, Geneva, Switzerland); Dong Eon Kim (PAL, Pohang, Republic of Korea); Kyung Sook Kim (PAL, Pohang, Republic of Korea); In Soo Ko (POSTECH, Pohang, Republic of Korea); Volker RW Schaa (GSI, Darmstadt, Germany) |
| ISBN |
978-3-95450-147-2 |
| Published |
June 2016 |
| Copyright |
|