          <title>
             Methodology, Characterisation and Results from the Prototype Beam Loss Monitoring ASIC at CERN
          </title>
       </titles>
       <publisher>JACoW Publishing</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>2673-5350</isbn>
		 <isbn>978-3-95450-230-1</isbn>
		 <electronic-resource-num>10.18429/JACoW-IBIC2021-TUPP34</electronic-resource-num>
		 <language>English</language>
		 <pages>294-298</pages>
       <keywords>
          <keyword>radiation</keyword>
          <keyword>monitoring</keyword>
          <keyword>data-analysis</keyword>
          <keyword>real-time</keyword>
          <keyword>interface</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2021</year>
          <pub-dates>
             <date>2021-10</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>https://doi.org/10.18429/JACoW-IBIC2021-TUPP34</url>
              <url>https://jacow.org/ibic2021/papers/tupp34.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          The characterisation of novel beam loss monitoring front-end converters, based on radiation-hardened application-specific integrated circuits (ASIC), is undergoing at CERN. An effective performance analysis of the newly developed ASICs plays a key role in their candidacy for the future installation in the HL-LHC complex. This work introduces the latest test-bed architecture, used to characterise such a device, together with the variety of audits involved. Special focus is given on the verification methodology of data acquisition and measurements, in order to allow a detailed study of the conversion capabilities, the evaluation of the device resolution and the linearity response. Finally, the first results of post-irradiation measurements are also reported.