| Title |
Preliminary Study on IPM for CADS Injector I |
| Authors |
- J. He, J.S. Cao, Y.F. Sui, J.H. Yue
IHEP, Beijing, People's Republic of China
|
| Abstract |
Beam profile determination at high intensity hadron accelerators implies the usage of non-invasive methods. The transverse profile of the beam is monitored via detecting the ionization products produced by the collision of proton with residual gas in the vacuum pipe. High voltage electrodes are used for producing guide electrical field and MCP for amplify the signal. The screen and CCD system are used for position detection. An ionization profile monitor is designed and manufactured. It has been installed on the ADS injector I. The signal intensity of ionization products matches the theory's expectation. Experiments result shows that it is a useful tool to measure the profile of proton beam.
|
| Paper |
download WEPCC13.PDF [0.610 MB / 3 pages] |
| Export |
download ※ BibTeX
※ LaTeX
※ Text/Word
※ RIS
※ EndNote |
| Conference |
IBIC2017, Grand Rapids, MI, USA |
| Series |
International Beam Instrumentation Conference (6th) |
| Proceedings |
Link to full IBIC2017 Proccedings |
| Session |
Wednesday Poster |
| Date |
23-Aug-17 16:00–18:00 |
| Main Classification |
6 Beam Profile Monitors |
| Keywords |
ion, electron, proton, experiment, detector |
| Publisher |
JACoW, Geneva, Switzerland |
| Editors |
Zhengzheng Liu (FRIB, East Lansing, MI, USA); Steven Lidia (FRIB, East Lansing, MI, USA); Amy McCausey (FRIB, East Lansing, MI, USA); Volker RW Schaa (GSI, Darmstadt, Germany) |
| ISBN |
978-3-95450-192-2 |
| Published |
March 2018 |
| Copyright |
|