Paper |
Title |
Page |
TUPC16 |
Ultimate Resolution of Soleil X-Ray Pinhole Camera
|
180 |
|
- M.-A. Tordeux, L. Cassinari, O. V. Chubar, J.-C. Denard, D. Pédeau, B. Pottin
SOLEIL, Gif-sur-Yvette
|
|
|
During the commissioning of the SOLEIL Storage Ring, beam emittances have been measured with an X-ray pinhole camera system. The evolution of the system and its performances are presented here. As a result of the excellent alignment of the ring magnets, the vertical beam size is smaller than expected, that led us to an effort towards improving the initial resolution of the instrument. A high sensitivity CCD camera allows us to select the harder X-ray part of the radiation which is a key element for resolution improvement. Finally an evaluation of the ultimate pinhole resolution is made for SOLEIL.
|
|