A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   Y   Z  

Podadera Aliseda, I.

Paper Title Page
TUPB03 Precision Beam Position Monitor for EUROTeV 57
 
  • I. Podadera Aliseda, L. Søby
    CERN, Geneva
 
  For future linear colliders (ILC, CLIC) a new Precision Beam Position Monitor (PBPM) has been designed within the framework of EUROTeV. The design goals are a resolution of 100nm and an overall precision of 10μm, in a circular vacuum chamber of 6mm in diameter. The required bandwidth is 100 kHz-30MHz. The PBPM is based on an inductive type BPM which measures the image current in four electrodes located outside the vacuum tube, from which the position is derived. In this paper, the design of the PBPM is presented together with the first bench measurements, where twoμmovers and a rotational stage, installed on a vibration damped table, have been used to characterize the PBPM.