A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   Y   Z  

Marchetto, M.

Paper Title Page
WEPB07 Time Domain Diagnostics for the ISAC-II Superconducting Heavy Ion Linac 247
 
  • V. A. Verzilov, R. E. Laxdal, M. Marchetto, W. R. Rawnsley
    TRIUMF, Vancouver
 
  The medium beta section of the ISAC-II superconducting linac has 20 bulk niobium quarter wave resonators and adds up to 20 MV of energy to the 1.5Mev/u and A/q<=6 ion beam injected from the ISAC-I accelerators. The commissioning of this new linac started April 2006 and the first radioactive beam was delivered to an experiment in January 2007. A standard array of ISAC diagnostics were added to the ISAC-II section to commission and tune the transport beamline and linac optics. In addition two new devices were developed: an ion implanted silicon detector measuring beam particles scattered from a gold foil and time of flight (TOF) monitors based on micro-channel plates. These are used both to tune the LINAC and to characterize the accelerated beams in the longitudinal phase space. The TOF monitors have the time resolution below 100ps, energy resolution of 0.1% and dynamic range spanning 6 orders of magnitude. Data acquisition and analysis is highly automatic and integrated into the EPICS based ISAC control system. Design of the monitors and first measurements will be presented.