A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   Y   Z  

Kalekin, O.

Paper Title Page
TUPC02 Photo Injector Cathode Laser Beam Intensity and Pointing Position Diagnostics at PITZ 147
 
  • Ye. Ivanisenko, G. Asova, J. W. Bähr, S. A. Korepanov, M. Krasilnikov, B. Petrosyan, F. Stephan
    DESY Zeuthen, Zeuthen
  • O. Kalekin
    Erlangen University, Erlangen
 
  A photo cathode laser with unique parameters is used at the Photo Injector Test facility at DESY in Zeuthen, PITZ. It is cabable of producing laser pulse trains consisting of up to 800 pulses with a repetition rate of 1 MHz where each laser pulse has a flat-top temporal profile. The knowledge of the laser stability is very important for the emittance measurements procedure. Therefore, a system for monitoring the laser beam intensity and pointing position stability was created at PITZ. It is capable of measuring the laser spot position and pulse intensity for each of the laser pulses in the train using a quadrant diode and a photomultiplier tube, respectively. Taking into account the laser beam spot transverse intensity distribution measured by a CCD camera allows to study the position of the laser spot on the photo cathode with a resolution of 8.3 um. Laser intensity measurements can be done for a wide dynamical range of intensities due to the tunable photo multiplier tube gain. The first experiments with the new system show very small laser spot position jitter on the cathode surface of about 20 um and laser intensity fluctuations of about 14 %.