Segmented Beam Dump for Time Resolved Spectrometry on a High Current Electron Beam
|
340 |
|
- T. Lefèvre, H.-H. Braun, E. Bravin, C. Dutriat, C. P. Welsch
CERN, Geneva
|
|
|
In the CLIC Test Facility 3, the strong coupling between the beam and the accelerating cavities induces transient effects such that the head of the pulse is accelerated twice as much as the rest of the pulse. Three spectrometer lines are installed along the linac with the aim of measuring energy spread versus time with a 20ns resolution. The major difficulty is due to the high power carried by the beam which imposes extreme constraints of thermal and radiation resistances for the detector. This paper presents the design and the performances of a simple and easy-to-maintain device, called segmented dump. In this device, the particles are stopped inside metallic plates and the deposited charge is measured in the same way as in faraday cups. Simulations were carried out with the Monte Carlo code FLUKA in order to evaluate the problems coming from the energy deposition and find ways to prevent or reduce them. The detector resolution has been optimized by choosing the adequate material and thickness for the plates. The overall layout of the monitor is described with a special emphasis on its mechanical assembly. Finally, limitations arising at high beam energies are discussed.
|
|