A   B   C   D   E   F   G   H   I   J   K   L   M   N   O   P   Q   R   S   T   U   V   W   Y   Z  

Drago, A.

Paper Title Page
WEPB29 Bunch-by-Bunch Longitudinal Diagnostics at DAΦNE by IR Light 298
 
  • A. Bocci, M. C.G. Cestelli Guidi, A. Clozza, A. Drago, A. G. Grilli, A. Marcelli, A. R. Raco, R. S. Sorchetti
    INFN/LNF, Frascati (Roma)
  • E. P. Emanuele
    Università degli Studi di Firenze, Firenze
  • M. P. Piccinini
    Università Roma Tre, Roma
  • J. P. Piotrowski
    Vigo System Sa, Warsaw
 
  Compact uncooled HgCdTe semiconductor detectors optimized in the mid-IR range have been used to record time resolved single bunch synchrotron radiation (SR) emissions from the DAΦNE e- main ring. These devices allow a low cost bunch-by-bunch longitudinal diagnostics. Indeed, the detectors make possible to record a train of 2.7 ns long bunches per turn. A comparison with synchrotron light signals coming from the e+ ring is stimulating but at DAΦNE only two SR beamlines are operational and because of the lack of apertures in the main wall no easy alternatives exist for the e+ ring. To solve the problem, a compact SR port has been considered and is going to be implemented on the positron ring. A small dedicated vacuum chamber with a ZnSe infrared window and remote controlled mirrors will be installed to focus the light on the IR detectors. The source characteristics have been simulated and the optical system with the complete acquisition system will be described. When ready, the real time comparison between data collected on the two beams will be performed improving accelerator diagnostics and as a major tool to increase the stored currents in the e+ ring and the collider luminosity.  
WEO2A03 Advanced Measurements at the SPARC Photoinjector 224
 
  • A. Cianchi, L. Catani
    INFN-Roma II, Roma
  • D. Alesini, M. Bellaveglia, R. Boni, M. Boscolo, M. Castellano, E. Chiadroni, A. Clozza, L. Cultrera, G. Di Pirro, A. Drago, A. Esposito, M. Ferrario, D. Filippetto, V. Fusco, A. Gallo, G. Gatti, A. Ghigo, M. Incurvati, C. Ligi, E. Pace, L. Pellegrino, R. Ricci, C. Ronsivalle, C. Sanelli, M. Serio, F. Sgamma, B. Spataro, F. Tazzioli, S. Tomassini, C. Vaccarezza, M. Vescovi, C. Vicario
    INFN/LNF, Frascati (Roma)
  • A. Bacci, S. Cialdi, A. R. Rossi, L. Serafini
    INFN-Milano, Milano
  • A. M. Cook, M. P. Dunning, P. Frigola, P. Musumeci, J. B. Rosenzweig
    UCLA, Los Angeles, California
  • L. Giannessi, M. Quattromini
    ENEA C. R. Frascati, Frascati (Roma)
  • M. Migliorati, A. Mostacci, L. Palumbo
    Rome University La Sapienza, Roma
  • M. Petrarca
    INFN-Roma, Roma
 
  The objective of the first stage of the SPARC commissioning was the optimization of the RF-gun setting that best matches the design working point and a detailed study of the emittance compensation process providing the optimal value of emittance at the end of the linac. For this purpose an innovative beam diagnostic, the emittance-meter, consisting of a movable emittance measurement system, was conceived and built. More than a simple improvement over conventional, though non-trivial, beam diagnostic tools this device defines a new strategy for the characterization of new high performance photo-injectors. The emittance meter allows to measure at different location along the beamline the evolution of important beam parameters both in longitudinal and in the transverse phase space such as beam sizes, energy spread and rms transverse emittances in a region where the space-charge effect dominate the electron dynamics. The quality and the amount of the data allowed a clear reconstruction of the phase space evolution. We report also the first experimental observation of the double emittance minima effect on which is based the optimized matching with the SPARC linac