<xml>
  <records>
    <record>
       <contributors>
          <authors>
             <author>Thoeng, E.</author>
             <author>Laxdal, R.E.</author>
          </authors>
       </contributors>
       <titles>
          <title>
             Transient Study of Beam Loading and Feed-Forward LLRF Control of ARIEL Superconducting RF e-LINAC
          </title>
       </titles>
		 <publisher>JACoW</publisher>
       <pub-location>Geneva, Switzerland</pub-location>
		 <isbn>978-3-95450-178-6</isbn>
		 <electronic-resource-num>10.18429/JACoW-SRF2015-TUPB114</electronic-resource-num>
		 <language>English</language>
		 <pages>902-905</pages>
       <pages>TUPB114</pages>
       <keywords>
          <keyword>cavity</keyword>
          <keyword>controls</keyword>
          <keyword>linac</keyword>
          <keyword>beam-loading</keyword>
          <keyword>feedback</keyword>
       </keywords>
       <work-type>Contribution to a conference proceedings</work-type>
       <dates>
          <year>2015</year>
          <pub-dates>
             <date>2015-12</date>
          </pub-dates>
       </dates>
       <urls>
          <related-urls>
              <url>http://dx.doi.org/10.18429/JACoW-SRF2015-TUPB114</url>
              <url>http://srf2015.vrws.de/papers/tupb114.pdf</url>
          </related-urls>
       </urls>
       <abstract>
          ARIEL e-LINAC is a ½ MW-class SRF accelerator operated at 10 mA of average current. In the initial commissioning, e-LINAC will be tested with increasing duty factors from 0.1% up to CW mode. During the pulsed mode operation, beam loading causes cavity gradient fluctuation and therefore transient behaviour of SRF Cavity gradient needs to be studied in order to determine how the Low-level RF (LLRF) should be implemented. Performance of LLRF control system with and without non-adaptive feed-forward are simulated to determine the resulting beam energy spread and experimental measurements are proposed to measure the increase of beam size due to beam loading.
       </abstract>
    </record>
  </records>
</xml>