Keyword: higher-order-mode
Paper Title Other Keywords Page
MOP071 Record Quality Factor Performance of the Prototype Cornell ERL Main Linac Cavity in the Horizontal Test Cryomodule cavity, linac, cryomodule, experiment 300
 
  • N.R.A. Valles, R.G. Eichhorn, F. Furuta, G.M. Ge, D. Gonnella, D.L. Hall, Y. He, K.M.V. Ho, G.H. Hoffstaetter, M. Liepe, T.I. O'Connel, S. Posen, P. Quigley, J. Sears, V. Veshcherevich
    Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
 
  Funding: Supported by NSF grant DMR-0807731
Future SRF linac driven accelerators operated in CW mode will require very efficient SRF cavities with high intrinsic quality factors Q at medium accelerating fields. Cornell has recently finished testing the fully equipped 1.3 GHz, 7-cell main linac cavity for the Cornell Energy Recovery Linac in a horizontal test cryomodule (HTC). Measurements characterizing the fundamental mode’s quality factor have been completed, showing record Q performance. In this paper, we present detailed quality factor vs gradient results for three HTC assembly stages. We show that the performance of an SRF cavity can be maintained when installed into a cryomodule, and that thermal cycling reduces residual surface resistance. We present world record results for a fully equipped multicell cavity in a cryomodule, reaching intrinsic quality factors at operating accelerating field of Q(E =16.2 MV/m, 1.8K) > 6·1010 and Q(E =16.2 MV/m, 1.6K) > 1.0·1011, corresponding to a very low residual surface resistance of 1.1 nOhm.
 
 
THP048 The Influence of Tuners and Temperature on the Higher Order Mode Spectrum for 1.3 GHz SCRF Cavities cavity, HOM, quadrupole, dipole 1016
 
  • R. Ainsworth
    Royal Holloway, University of London, Surrey, United Kingdom
  • N. Baboi, M.K. Grecki, T. Wamsat
    DESY, Hamburg, Germany
  • N. Eddy
    Fermilab, Batavia, USA
  • S. Molloy
    ESS, Lund, Sweden
  • P. Zhang
    CERN, Geneva, Switzerland
 
  Higher Order Modes are of concern for superconducting cavities as they can drive instabilities and so are usually damped and monitored. With special dedicated electronics, HOMs can provide information on the position on the beam. It has been proposed that piezo tuners used to keep the cavities operating at 1.3 GHz could alter the HOM spectrum altering the calibration constants used to read out the beam position affecting long term stability of the system. Also, of interest is how the cavity reacts to the slow tuner. Detuning and the retuning the cavity may alter the HOM spectrum. This is of particular interest for future machines not planning to use dedicated HOM damping as the tuning procedure may shift the frequency of HOMs onto dangerous resonances. The effect of temperature on the HOM spectrum is also investigated. An investigation of these effects has been performed at FLASH and the results are presented including numerical simulations used to predict the resulting cavity distortion.