| Title |
Calibration of the Acceleration Voltage of Six Normal Conducting Cavities at ALBA |
| Authors |
- B. Bravo, U. Iriso, J. Marcos, J.R. Ocampo, F. Pérez, A. Salom, P. Solans
ALBA-CELLS Synchrotron, Cerdanyola del Vallès, Spain
|
| Abstract |
ALBA is a 3Gev synchrotron light source located in Barcelona and operating with users since May 2012. The ALBA storage ring uses six room temperature cavities; each one fed by two 80kW IOTs amplifiers at 499.654 MHz. An accurate calibration of the RF voltage is required for the right adjustment of the beam synchronous phase. In addition, if the ring accommodates several RF cavities, these may not be optimally phased with respect to each other, complicating the calculation of the total RF voltage. In this paper, the steps to calibrate the accelerating voltage of the SR cavities will be presented and different methodologies to cross-check these calibrations.
|
| Paper |
download WEPMN049.PDF [0.351 MB / 3 pages] |
| Export |
download ※ BibTeX
※ LaTeX
※ Text/Word
※ RIS
※ EndNote |
| Conference |
IPAC2015, Richmond, VA, USA |
| Series |
International Particle Accelerator Conference (6th) |
| Proceedings |
Link to full IPAC2015 Proccedings |
| Session |
Wednesday Posters (Monroe) |
| Date |
06-May-15 16:00–18:00 |
| Main Classification |
7: Accelerator Technology |
| Sub Classification |
T06 - Room Temperature RF |
| Keywords |
cavity, synchrotron, operation, coupling, pick-up |
| Publisher |
JACoW, Geneva, Switzerland |
| Editors |
Stuart Henderson (ANL, Argonne, IL, USA); Evelyn Akers (Jlab, Newport News, VA, USA); Todd Satogata (JLab, Newport News, VA, USA); Volker R.W. Schaa (GSI, Darmstadt, Germany) |
| ISBN |
978-3-95450-168-7 |
| Published |
June 2015 |
| Copyright |
|