| Title |
The Installation of TPS Booster Vacuum System |
| Authors |
- C.M. Cheng, B.Y. Chen, J.-R. Chen, G.-Y. Hsiung, S-N. Hsu, T.Y. Leepresenter, Y.C. Yang
NSRRC, Hsinchu, Taiwan
- J.-R. Chen
National Tsing Hua University, Hsinchu, Taiwan
|
| Abstract |
The booster of Taiwan Photon Source (TPS) is designed for 3GeV full energy injection ramped up from 150MeV. It is a synchrotron accelerator of 496.8m. The major vacuum system is elliptical tube made of 304 stainless steel. The inner cross section is 35*20 mm with 0.7 mm thickness. The elliptical tubes were chemical cleaned and ozonated water cleaned before installation. The bending tube was assembled and aligned into dipole magnet at laboratory. The BPM support and pumping chamber support was aligned with 0.3 mm deviation. The BPM chamber and pumping chamber was assembled firstly. The elliptical tube and bellows was installed to connect BPM, pumping chamber and bending chamber. The cold cathode gauge and TMP was mounted on pumping chamber. The pressure data and residual gas analysis will be described in the paper.
|
| Paper |
download WEPME052.PDF [0.579 MB / 3 pages] |
| Export |
download ※ BibTeX
※ LaTeX
※ Text/Word
※ RIS
※ EndNote |
| Conference |
IPAC2014, Dresden, Germany |
| Series |
International Particle Accelerator Conference (5th) |
| Proceedings |
Link to full IPAC2014 Proccedings |
| Session |
Poster Session, Messi Area |
| Date |
18-Jun-14 16:00–18:00 |
| Main Classification |
07 Accelerator Technology Main Systems |
| Sub Classification |
T14 Vacuum Technology |
| Keywords |
vacuum, booster, dipole, ion, synchrotron |