| Title |
Multi-Cell Temperature Mapping and Conclusions |
| Authors |
- F. Furuta, R.G. Eichhorn, G.M. Ge, D. Gonnella, D.L. Hartill, G.H. Hoffstaetter, J.J. Kaufman, M. Liepe, E.N. Smith
Cornell University (CLASSE), Cornell Laboratory for Accelerator-Based Sciences and Education, Ithaca, New York, USA
|
| Abstract |
Multi-cell temperature mapping (T-map) system has been developed and applied on SRF Nb cavities vertical tests (VT) at Cornell. It has nearly two thousand thermometers and achieved a 1mK resolution of niobium surface temperature rinsing in superfluid helium . We have upgraded the system to be capable of monitoring the temperature profiles of quench spot on cavity. The recent results of T-map during cavity tests and details will be reported.
|
| Paper |
download TUPB081.PDF [1.289 MB / 5 pages] |
| Poster |
download TUPB081_POSTER.PDF [4.426 MB] |
| Conference |
SRF2015, Whistler, BC, Canada |
| Series |
International Conference on RF Superconductivity (17th) |
| Proceedings |
Link to full SRF2015 Proccedings |
| Session |
Poster Session |
| Date |
15-Sep-15 14:30–17:40 |
| Main Classification |
SRF Technology - Cavity |
| Keywords |
cavity, SRF, monitoring, controls, cryogenics |