| Abstract |
Cooling speed significantly affects flux trapping of a SRF cavity, which will determine the residual resistance and the quality factor of the cavity. We measured the temperature distribution of a 9-cell cavity at different cooling speeds by the multi-cell T-map system of Cornell University. This paper proposed a method to evaluate the formation of a normal conducting island at different cooling speed. The fast cool-down and slow cool-down has been compared. We conclude that the slow cool-down freezes less normal conducting islands.
|