| Abstract |
An improved SRF gun has been installed and commissioned at HZDR since 2014. This new gun replaces the first SRF gun at the superconducting linear accelerator ELBE which had been in operation since 2007. The new SRF gun II has an improved 3.5-cell niobium cavity and a superconducting solenoid inside the gun cryostat. The gun has been tested first with a Cu photocathode. Using the standard high repetition rate laser system, this allows low bunch charge beams of a few pC only. The beam parameters for these low charges have been measured, and the first beam has been guided into the ELBE accelerator. Since 2015 the photocathode transfer system is installed for future use of Cs2Te photocathodes with high quantum efficiency photocathodes.
|
| Paper |
download TUIDLH1038.PDF [1.469 MB / 6 pages] |
| Slides |
download TUIDLH1038_TALK.PDF [7.973 MB] |
| Conference |
ERL2015, Stony Brook, NY, USA |
| Series |
ICFA Advanced Beam Dynamics Workshop on Energy Recovery Linacs (56th) |
| Proceedings |
Link to full ERL2015 Proccedings |
| Session |
WG1 ERL Injectors (Gun/Cathode/Laser) |
| Date |
09-Jun-15 15:55–17:35 |
| Main Classification |
WG1 ERL Injectors (Gun/Cathode/Laser) |
| Keywords |
laser, gun, SRF, cavity, electron |
| Publisher |
JACoW, Geneva, Switzerland |
| Editors |
Sergey Belomestnykh (FNAL, Batavia, IL, USA); Caitlin M. Hoffman (BNL, Brookhaven, NY, USA); Volker RW Schaa (GSI, Darmstadt, Germany) |
| ISBN |
978-3-95450-183-0 |
| Published |
September 2015 |
| Copyright |
|